Sign In | Join Free | My burrillandco.com
Home > Differential Scanning Calorimeter >

Industrial Differential Scanning Calorimeter Featuring Widescreen Touch Interface for Accurate Polymer Oxidation Induction Period Measurement

Beijing Tonghe Testing Machine Co., ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Industrial Differential Scanning Calorimeter Featuring Widescreen Touch Interface for Accurate Polymer Oxidation Induction Period Measurement from wholesalers
     
    Buy cheap Industrial Differential Scanning Calorimeter Featuring Widescreen Touch Interface for Accurate Polymer Oxidation Induction Period Measurement from wholesalers
    • Buy cheap Industrial Differential Scanning Calorimeter Featuring Widescreen Touch Interface for Accurate Polymer Oxidation Induction Period Measurement from wholesalers
    • Buy cheap Industrial Differential Scanning Calorimeter Featuring Widescreen Touch Interface for Accurate Polymer Oxidation Induction Period Measurement from wholesalers

    Industrial Differential Scanning Calorimeter Featuring Widescreen Touch Interface for Accurate Polymer Oxidation Induction Period Measurement

    Ask Lasest Price
    Brand Name : TH
    Model Number : DSC-ZS5
    Certification : ISO9001 CE
    Payment Terms : L/C,D/A,D/P,T/T,Western Union,MoneyGram
    Supply Ability : 20 sets per month
    Delivery Time : 10~15 work days
    • Product Details
    • Company Profile

    Industrial Differential Scanning Calorimeter Featuring Widescreen Touch Interface for Accurate Polymer Oxidation Induction Period Measurement

    Industrial Differential Scanning Calorimeter Featuring Widescreen Touch Interface for Accurate Polymer Oxidation Induction Period Measurement



    Summary:

    This DSC (Differential Scanning Calorimeter) features a touchscreen interface, specifically engineered for the oxidation induction period (OIT) testing of polymeric materials. It supports one-key operation for users and full software automation—streamlining testing workflows and ensuring consistent, error-free operation.

    The instrument fully complies with the following international and national standards:

    • GB/T 19466.2-2009 / ISO 11357-2:1999
    • GB/T 19466.3-2009 / ISO 11357-3:1999
    • GB/T 19466.6-2009 / ISO 11357-6:1999


    Features:

    • Industrial-Grade Widescreen Touch Interface

      Boasts an information-rich display presenting comprehensive real-time data, including set temperature, sample temperature, oxygen flow rate, nitrogen flow rate, differential thermal signal, and various switch statuses—facilitating intuitive monitoring and operation.
    • Universal USB Communication Interface

      Features high universality and reliable data transmission, with built-in self-recovering connection functionality. This ensures stable communication with external devices and minimizes interruptions during testing.
    • Compact Furnace with Adjustable Thermal Rates

      Adopts a compact furnace structure, supporting stepless adjustment of heating and cooling rates to meet the thermal cycle requirements of different polymeric material OIT tests.
    • Optimized Installation & Anti-Contamination Design

      Equipped with an improved installation process and adopts a mechanical fastening method. This completely eliminates contamination of the differential thermal signal caused by internal furnace colloid, ensuring the accuracy of test data.
    • Efficient Heating & Cooling System

      The furnace utilizes electric heating wires for heating and circulating cooling water (compressor-refrigerated) for cooling. It features a compact structure and small footprint, saving laboratory space while ensuring efficient thermal regulation.
    • High-Precision Temperature Control

      Dual temperature probes guarantee excellent repeatability of sample temperature measurement. Specialized temperature control technology is employed to regulate the furnace wall temperature, thereby achieving precise control of the sample’s set temperature.
    • Automatic Gas Channel Switching

      The gas flow meter enables automatic switching between two gas channels, with fast switching speed and short stabilization time—ensuring consistent gas atmosphere conditions during testing.
    • Standard Reference Samples for Calibration

      Comes with standard reference samples, facilitating convenient calibration of temperature coefficients and enthalpy coefficients to maintain long-term testing accuracy.
    • Versatile Software Compatibility

      The software supports screens of all resolutions, automatically adjusting the computer screen size and curve display mode. It is fully compatible with laptops and desktops, and supports multiple operating systems including Windows 2000, XP, Vista, Windows 7, Windows 8, and Windows 10.
    • Customizable Automated Operation

      Supports users in editing device operation modes based on actual testing requirements, realizing full automation of measurement steps. The software provides dozens of configurable instructions, allowing users to flexibly combine and save instructions according to specific test procedures—simplifying complex operations into one-click execution.
    • Fully Enclosed Protective Structure

      Adopts a fully enclosed support structure design, which prevents foreign objects from falling into the furnace body, avoids furnace contamination, and reduces maintenance frequency.

    Parameters:

    Temperature range0℃~500℃
    Temperature resolution0.01℃
    Heating rate0.1~40℃/min
    Cooling rate0.1~20℃/min
    Calorimetric resolution100%.
    Constant temperature5℃~500℃
    Duration of constant temperatureThe duration is recommended to be less than 24 hours.
    Temperature control modeHeating, cooling, constant temperature
    DSC range0~±500mW
    DSC resolution0.01mW
    DSC sensitivity0.01mW
    Working powerAC 220V 50Hz 300W or other
    Atmosphere control gasTwo-channel gas control by automatic controlled (e.g. nitrogen and oxygen)
    Gas flow0-200mL/min
    Gas pressure0.2MPa
    Gas flow accuracy0.2mL/min
    CrucibleAluminium crucible Φ6.6*3mm (Diameter * High)
    Calibration standardwith standard material (indium, tin, zinc)
    Data interfaceStandard USB interface
    Display mode7-inch touch screen
    Output modecomputer and printer


    Configuration list:

    DSC machine1 set
    Aluminium crucibles300 pieces
    Power cords and USB cableEach one
    CD (contains software and operations video)One
    Soft-keyOne
    Oxygen airway and nitrogen airwayEach 5m
    Operation manualOne
    Standard sample(contains Indium, tin, zinc)Each one
    Tweezer and medicine spoonEach one
    Custom pressure reducing valve joint and quick jointTwo
    Fused glass fusesFour
    External circulation thermostat sinkOne
    Water pipeOne


    Furnace bracket:


    Software screenshots:

    Quality Industrial Differential Scanning Calorimeter Featuring Widescreen Touch Interface for Accurate Polymer Oxidation Induction Period Measurement for sale