Sign In | Join Free | My burrillandco.com
Home > Differential Scanning Calorimeter >

Plastics 500mW Differential Scanning Calorimeter Instrument DSC-600

Beijing Tonghe Testing Machine Co., ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Plastics 500mW Differential Scanning Calorimeter Instrument DSC-600 from wholesalers
     
    Buy cheap Plastics 500mW Differential Scanning Calorimeter Instrument DSC-600 from wholesalers
    • Buy cheap Plastics 500mW Differential Scanning Calorimeter Instrument DSC-600 from wholesalers

    Plastics 500mW Differential Scanning Calorimeter Instrument DSC-600

    Ask Lasest Price
    Brand Name : JINHAIHU
    Model Number : DSC-600
    Certification : ISO 9001
    Payment Terms : T/T,L/C,Western Union,MoneyGram,D/A,D/P
    Supply Ability : 20 sets per month
    Delivery Time : 7-15 working days
    • Product Details
    • Company Profile

    Plastics 500mW Differential Scanning Calorimeter Instrument DSC-600

    Plastics-Differential scanning calorimeter(DSC)


    Brief introduction of the instrument:

    Differential scanning calorimetry (DSC) is a classic thermal analysis technique for measuring thermal effects under programmed temperature control. It is widely applied in multiple material and chemical fields, including R&D, process optimization, quality control, and failure analysis. Using DSC, one can study phase transitions in inorganic materials, melting and crystallization processes of polymer materials, drug polymorphism, and solid/liquid phase ratios in oils and fats.


    Instrument use:

    Measurements include physical and chemical changes related to heat, such as glass transition temperature, melting point, melting temperature, crystallization and crystallization heat, phase transformation reaction heat, thermal stability, curing/crosslinking, and oxidation induction period of the product.


    Reference standard:

    GB/T 19466.2–2004/ISO 11357 - 2:1999, Part 2: Assessment of glass transition temperature.
    GB/T 19466.3–2004/ISO 11357 - 3:1999, Part 3: Measurement of melting and crystallization temperature as well as enthalpy.
    GB/T 19466.6 - 2009/ISO 11357 - 3:1999, Part 6: Determination of oxidation induction time (isothermal OIT) and oxidation induction temperature (kinetic OIT).

    Main feature:
    1.The brand-new fully enclosed metal furnace body design structure significantly enhances resolution and accuracy, as well as provides better baseline stability.
    2. Professional alloy sensors are adopted, which are more resistant to corrosion and oxidation, and have high sensor sensitivity.
    3. A complete two-channel atmosphere control system precisely controls the purge gas flow rate. The software Settings automatically switch, and the data is directly recorded in the database.

    Technical parameter:


    DSCDSC-600 Differential Scanning Calorimeter
    DSC Range0~±500mW
    Temperature RangeRoom temperature ~ 800℃ Air cooling
    Heating Rate0.1~80 ℃/min
    Temperature Resolution0.1℃
    Temperature Fluctuation±0.1℃
    Temperature Repeatability±0.1℃
    DSC Noise0.01mW
    DSC Resolution0.01mW
    DSC Accuracy0.01mW
    DSC Sensitivity0.01mW
    Temperature Control ModeHeating, constant temperature (full program automatic control)
    Curves ScanHeating scan
    Atmosphere ControlInstrument automatically switches
    Display24bit color 7-inch LCD touch-screen display
    Data InterfaceStandard USB interface
    Parameter StandardsWith a standard substance; a key calibration function; the user can correct the temperature and enthalpy personally.
    RemarkAll the technical indicators can be adjusted according to user needs.